Datasheet · MRM75os Datasheet · HVAC/R Tools MRM75os Wipcool MRM75os Refrigerant Recovery Machine with Oil SeparatorRefrigerant recovery machine with a built-in oil separator and an oil-free twin-piston compressor, for group III–V refrigerants, including R32, R1234yf (class A2L) and R410A. Liquid recovery of group V refrigerants up to 3.9 kg/min.  3,9kg/minLiquid recovery, group V 0,7kg/minVapour recovery, group V 10,5kg/minPush/Pull, group V 11,6kgWeight 1. What it is used forThe MRM75os is a refrigerant recovery machine with a built-in oil separator. It has an air-cooled, oil-free twin-piston compressor with a 970 W motor. The machine recovers group III, IV and V refrigerants, including R32 and R1234yf (class A2L) and R410A.
Refrigerant can be recovered as vapour or liquid, or using the Push/Pull method, with the mode selected using a dial. The digital display and control keys are on top of the housing. Once recovery is complete, the machine cleans itself with the dial in the PURGE position. - Oil separator with drain. The built-in separator separates oil from the recovered refrigerant, and the drain tube allows it to be drained from the machine.
- Twin-piston compressor. The twin-piston compressor recovers group V refrigerants as liquid at 3.9 kg/min, and at 10.5 kg/min using the Push/Pull method.
- Switch-off after recovery. In LP1 mode, the machine switches off automatically when recovery is complete and displays COMPLETE. In LP2 mode, it runs continuously.
- Rear access to the compressor. A service port at the rear of the housing makes it easier to replace the compressor piston rings.
2. In the boxMRM75os refrigerant recovery machine Power cableLength 1.8 m Filter Shoulder strap Service hose User manual 3. Technical specifications| Power supply | 230 V |
|---|
| Motor power | 970 W |
|---|
| Motor speed | 3000 rpm |
|---|
| Max. current | 6,5 A |
|---|
| Compressor | Oil-free, air-cooled, piston |
|---|
| Automatic shut-off | 38,5 bar |
|---|
| Operating temperature | 0–40 °C |
|---|
| Dimensions (L × W × H, mm) | 386 × 255 × 276 |
|---|
| Net weight | 11,6 kg |
|---|
| Oil separator | With separator |
|---|
| Outer pack | 1 pc. |
|---|
| Group III refrigerants | R134a, R401C, R406A, R500, R1234yf |
|---|
| Group IV refrigerants | R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509 |
|---|
| Group V refrigerants | R402A, R404A, R407A, R407B, R410A, R507, R32 |
|---|
| Vapour recovery (groups III / IV / V) | 0.5 / 0.7 / 0.7 kg/min |
|---|
| Liquid recovery (groups III / IV / V) | 2.6 / 3.0 / 3.9 kg/min |
|---|
| Push/Pull (groups III / IV / V) | 8.2 / 9.3 / 10.5 kg/min |
|---|
Features and equipment- Built-in oil separator, oil drainage through a drain tube
- Air-cooled, oil-free twin-piston compressor, 970 W motor
- Vapour recovery, liquid recovery and Push/Pull method
- Mode selector dial: VAPOUR FAST, RECOVER, LIQUID THROTTLE, CLOSE, PURGE
- Self-cleaning in the PURGE position
- Digital inlet (IN) and outlet (OUT) pressure display, keys on top of the housing
- Pressure units: inHg, kPa, psi, kgf, bar, MPa; display zeroing
- LP1 mode - switch-off after recovery; LP2 mode - continuous operation
- Internal 38.5 bar high-pressure switch with HP message and alarm
- Audible alarm with reset and mute mode
- Restart after a fault has been resolved (RESTART)
- Error codes F1–F8, including overload, undervoltage and overvoltage
- Temperature sensor and temperature protection
- Service port at the rear of the housing - replacement of piston rings and air valve cores
4. ApplicationsLarge systems - Push/Pull methodIn large systems containing more than 10 kg of liquid refrigerant, the machine recovers it using the Push/Pull method. 5. Warranty and documents24-month warranty Documents to downloadSpecifications are subject to change without notice.As of 11/2026 |