Wipcool MRH-1 user manual
Read the entire manual before first use. Keep it for as long as you use the device.

Wipcool MRH user manual
Wipcool MRH hoses are designed for servicing systems with high-pressure refrigerants, including R410A and R32. Sets are available without valves, with CV60° ball valves and with SV service valves.
The user manual is an integral part of the product. Please read this manual carefully and follow all instructions closely.
Symbols and conventions
- 01
Warning - read the text in the box next to the symbol.
Safety information
- ■Do not connect hoses to connections of a different size.
Technical specifications
The length in the table applies to each hose in the set.
Without valves
| Parameter | MRH-1 | MRH-2 |
|---|---|---|
| Working pressure | 55 bar | 55 bar |
| Length | 150 cm | 150 cm |
| Connections - yellow | 1/4" - 1/4" | 1/4" - 1/4" |
| Connections - red | 1/4" - 5/16" | 1/4" - 1/4" |
| Connections - blue | 1/4" - 5/16" | 1/4" - 1/4" |
With ball valves
| Parameter | MRH-1CV60° | MRH-2CV60° |
|---|---|---|
| Working pressure | 55 bar | 55 bar |
| Length | 150 cm | 150 cm |
| Connections - yellow | 1/4" - 1/4" | 1/4" - 1/4" |
| Connections - red | 1/4" - 5/16" | 1/4" - 1/4" |
| Connections - blue | 1/4" - 5/16" | 1/4" - 1/4" |
With service valves
| Parameter | MRH-1SV | MRH-2SV |
|---|---|---|
| Working pressure | 55 bar | 55 bar |
| Length | 180 cm | 180 cm |
| Connections - yellow | 1/4" - 1/4" | 1/4" - 1/4" |
| Connections - red | 1/4" - 5/16" | 1/4" - 1/4" |
| Connections - blue | 1/4" - 5/16" | 1/4" - 1/4" |
Construction






MRH-1 hose construction

The MRH-1 hose has a protective layer, a reinforcing layer and an inner layer that limits refrigerant permeation. The connection nuts are made of brass.
Set contents
Each MRH set contains three hoses: yellow, red and blue.
Connection
- 01Check the model designation and select the connections according to the technical specifications table.
- 02Check the condition of the hoses and connections before connecting them.
Connect the hoses according to the instructions for the instrument being connected.
Operation
Models without valves do not shut off flow through the hose. The ball valve on the CV60° variant is used to open and shut off flow. The SV service valves shut off flow and allow the hose to be disconnected with less refrigerant loss. Closing the valve alone does not remove refrigerant or pressure trapped in the hose.
Finishing work
- 01If refrigerant remains in the hose, recover it using a refrigerant recovery machine.
- 02Make sure that the section being disconnected is no longer under pressure, and disconnect the hoses.
Service and documents
Before submitting a service request, prepare:
- ■Model - shown on the product label and on the invoice.
- ■Serial number - if there is none, provide the production number (e.g. 11/2025), usually found on the underside of the product.
- ■Proof of purchase - an invoice or receipt from an authorised distributor.
- ■Description of the fault - what is happening, when it started and under what conditions.
You can submit a service request at wipcool.pl/serwis. You will also find the warranty terms there.