Wipcool MRS10 Refrigerant Charging Scale
Refrigerant charging scale with a solenoid valve for charging systems with A3 refrigerants, such as R290 and R600a, and recovering them by weight. It has a 10 kg capacity and 1 g resolution.
- A3 refrigerants
- Solenoid valve
- Charging and recovery modes
- Upright or inverted cylinder
- 24-month warranty
- Warranty service in Poland
- Service by the distributor in the country of purchase
The MRS10 refrigerant charging scale is used to charge systems with A3 refrigerants, such as R290 and R600a, and recover them by weight. The built-in solenoid valve opens the flow and automatically closes it when the scale measures the set amount of refrigerant - a minimum of 50 g.
The platform has a 10 kg capacity and 1 g resolution. The scale is powered by the 3 supplied 18650 batteries, which are charged in the scale via a USB-C port. A full charge provides up to 60 h of operation.
In the box
- MRS10 refrigerant charging scale
- R290/R600a cylinder adapter7/16"-20 UNF to 7/16"-28 UNEF, female
- Li-ion 18650 batteries3 pcs., 3.7 V, 2400 mAh
- User manual
Technical specifications
| Capacity | 10 kg |
| Minimum increment (resolution) | 1 g |
| Accuracy | 0,05% |
| Units | kg / oz / lb |
| Operating temperature | 0–50 °C |
| Storage temperature | from -10 to +60 °C |
| Power supply | 3 × 3.7 V Li-ion battery (18650/2400 mAh) |
| Operating time | 60 h (full charge) |
| Accessories | R290/R600a adapter (7/16"-20 UNF → 7/16"-28 UNEF) |
| Resolution | 1 g |
| Minimum charging and recovery batch | 50 g |
| Minimum weighing weight | 100 g |
| Packaging | tool bag |
| Outer packaging | 5 pcs. |
Features and equipment
This equipment must only be operated by qualified personnel. Read the user manual before first use.