Wipcool S1 / S1.5 / S2 user manual
The Wipcool S1, S1.5 and S2 are single-stage rotary vane vacuum pumps for evacuating sealed systems.
The user manual is an integral part of the product. Please read this manual carefully and follow all instructions closely.
General information
Wipcool products are designed for professional use by qualified air conditioning and refrigeration engineers. As the manufacturer, Wipcool specifies that our equipment should be operated only by suitably qualified and trained personnel.
- ■Observe all local safety regulations and general safety standards when using the Wipcool S1, S1.5 or S2 vacuum pump.
- ■The user manual should be kept near the device so that personnel can access it easily at any time.
- ■Before use, qualified personnel should read the user manual carefully and understand all the instructions it contains.
- ■The manufacturer accepts no liability for any damage resulting from improper use, failure to follow the user manual, lack of personnel qualifications or any unauthorised modifications to the device.
- ■The general terms and conditions of sale contained in the sales documents apply.
Symbols and conventions
Signs and markings used on the device and in the manual:
- 01
Indicates that the product complies with the health, safety and environmental standards applicable in the European Union.
- 02RoHSThe product meets the requirements for restricting the use of hazardous substances.
- 03
Do not dispose of the pump with household waste.
- 04
Warning - read the text in the box next to the symbol.
- 05
Hazardous voltage - risk of electric shock.
- 06
Warning of flammable materials.
Safety information
- ■The temperature of the gas drawn in must not exceed 40 °C. Use the pump at an ambient temperature of 5–45 °C.
Technical specifications
| Parameter | S1 | S1.5 | S2 |
|---|---|---|---|
| Power supply | 230 V~ / 50–60 Hz | 230 V~ / 50–60 Hz | 230 V~ / 50–60 Hz |
| Number of stages | 1 | 1 | 1 |
| Ultimate vacuum | 150 microns (0.2 mbar) | 150 microns (0.2 mbar) | 150 microns (0.2 mbar) |
| Power | 190 W | 190 W | 250 W |
| Maximum flow rate | 57 l/min | 85 l/min | 113 l/min |
| Oil capacity | 230 ml | 210 ml | 200 ml |
| Inlet connection | 1/4" SAE | 1/4" SAE | 1/4" SAE |
| Operating temperature | 5–45 °C | 5–45 °C | 5–45 °C |
| Maximum inlet gas temperature | 40 °C | 40 °C | 40 °C |
| Dimensions (L × W × H) | 266 × 121 × 194 mm | 266 × 121 × 194 mm | 266 × 121 × 194 mm |
Device diagram
The pump has a transparent oil reservoir and a built-in non-return valve. Protective features limit oil leakage when the pump is tilted and reduce oil splashing.
The oil filler cap is above the oil reservoir, and the drain screw is below it.
Dimensions
| Label | Dimension | Label | Dimension |
|---|---|---|---|
| A | 145 mm | F | 138 mm |
| B | 36 mm | G | 70 mm |
| C | 107 mm | H | 69 mm |
| D | 266 mm | I | 194 mm |
| E | 73 mm | J | 121 mm |
Contents
- ■Vacuum pump.
- ■Vacuum pump oil.
- ■User manual.
A vacuum hose is not included.
After unpacking, check that all items are present and in good condition. Report any missing items, damage or oil leaks in the packaging to the seller.
Transport and storage
- ■Transport the pump in its original packaging.
- ■Store the pump in a dry place, away from direct sunlight and heat sources.
- ■Store the pump at a temperature of -20 to +60 °C.
Applications
The pumps are intended for light servicing work involving the evacuation of refrigeration equipment, split system air conditioners, small refrigeration systems and vehicle air conditioning systems. The pumps can also be used in other high-vacuum systems, such as vacuum packaging, gas analysis, thermoplastic forming, printing equipment and medical equipment.
How to use
Before first use


Topping up the oil
If the oil level is below halfway up the oil sight glass, top up the oil as for the initial fill (steps 1–2 above). Disconnect the pump from the power supply before unscrewing the oil filler cap.
Starting the pump
Before each use, check the condition of the pump and accessories and the oil level. If necessary, top up the oil according to the ‘Topping up the oil’ section above.


Maintenance
General recommendations
Change the oil when it turns black, becomes cloudy (emulsified) or is contaminated.
Changing the oil
- 01Unscrew the drain screw beneath the oil reservoir and drain the oil. Then tighten the drain screw.
- 02Unscrew the oil filler cap and slowly pour in fresh vacuum pump oil. The built-in oil leak protection limits the filling rate.
- 03Connect the pump to the power supply and start it using the switch. Check that the oil level has stabilised halfway up the oil sight glass.
- 04Switch off the pump and disconnect it from the power supply. Screw in the oil filler cap.
Troubleshooting
| Problem | Possible cause | Solution |
|---|---|---|
| Insufficient vacuum | Insufficient oil | Top up the oil to halfway up the oil sight glass. |
| Insufficient vacuum | Oil is emulsified or contaminated | Change the oil. |
| Insufficient vacuum | Blocked oil inlet or insufficient oil supply | Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Insufficient vacuum | Leaking hoses or leaks in the system being evacuated | Check the hoses and system for leaks; repair any leaks. |
| Insufficient vacuum | Incorrectly selected pump, e.g. too small | Select a pump suited to the size of the system being evacuated. |
| Insufficient vacuum | Worn parts, increased clearances or a leaking line inside the pump | Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Insufficient vacuum | Contamination on the sealing surface of the oil filler cap | Check for and remove any contamination. |
| Oil leaks | Worn shaft seal | Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Oil leaks | Loose or damaged oil reservoir connection | Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Difficult starting | Low oil temperature | Start the pump with the inlet connection open to the atmosphere and leave it running until the oil warms up. |
| Difficult starting | Motor or power supply problem | Check the power supply. If it is working correctly, stop work. Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Difficult starting | Contamination inside the pump | Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
| Pump does not start or stops suddenly | Motor or power supply problem | Check the power supply. If it is working correctly, stop work. Have the pump repaired by the service team - submit a service request at wipcool.pl/serwis. |
Waste electrical and electronic equipment
- 01
The crossed-out bin symbol means that the device must not be disposed of with other waste at the end of its life.
Under applicable regulations on waste electrical and electronic equipment, products marked with the separate collection symbol must not be disposed of with other municipal waste. Because they contain hazardous substances, electronic products that are not collected separately may pose a risk to the environment and human health. Proper separate collection of waste electrical and electronic equipment prevents adverse effects on the environment.
By taking waste equipment to a collection point, the user contributes to its reuse, recycling and recovery.
Recycling - one method of protecting the environment. The process of recovering substances from waste that can be reused as raw materials.
Waste recovery - the use of waste that has lost its useful value, such as plastics, paper and cardboard, as secondary raw materials; the term is also commonly used to mean the destruction of waste.
Information about the waste electrical and electronic equipment collection system
- ■Waste electrical and electronic equipment must not be disposed of together with other waste.
- ■The collection of incomplete electrical and electronic equipment and parts from waste equipment is prohibited.
- ■A distributor delivering equipment intended for households to a purchaser must collect household waste equipment free of charge at the place of delivery, provided that the waste equipment is of the same type and serves the same function as the equipment delivered.
- ■The user may hand over waste equipment to a waste equipment collector, a treatment facility or a municipal waste collector operating in the municipality.
- ■Information about collection points is available on the Public Information Bulletin (BIP) websites of the regional, city and municipal authorities.
Service and documents
Before submitting a service request, prepare:
- ■Model - shown on the device nameplate and on the invoice.
- ■Serial number - if there is none, provide the production number (e.g. 11/2025), usually found on the underside of the device.
- ■Proof of purchase - an invoice or receipt from an authorised distributor.
- ■Description of the fault - what is happening, since when and under what conditions.
You can submit a service request at wipcool.pl/serwis. You will also find the warranty terms there.